Experimental Investigation of Heat Transfer from a 2 × 2 Rod Bundle to Supercritical Pressure Water

Han Wang,Qincheng Bi,Linchuan Wang,Haicai Lv,Laurence K. H. Leung
DOI: https://doi.org/10.1016/j.nucengdes.2014.04.036
2016-01-01
Abstract:The experiment was performed to study the heat transfer of supercritical water in wire-wrapped 2 × 2 rod bundle under the background of supercritical water-cooled reactor fuel qualification test.The experimental parameters cover the pressure of 23 to 28 MPa,mass flux of 400 to 1 000 kg/(m2 ·s)and heat flux of 200 to 1 000 kW/m2 .The circumferential wall temperature distributions of the heated tubes were obtained.In addition,the effects of heat flux,mass flux,pressure and wire-wrapped spacer on wall temperature and heat transfer coefficient were analyzed.It is found that the wall temperatures along the circumferential direction of the heated tube are non-uniform and non-symmetric.The highest wall temperature appears either at the corner sub-channel,or at the location covered by the wrapped wire.The heat transfer coeffi-cient drops considerably with increasing heat flux or decreasing mass flux in the pseudo-critical region,but varies slightly at different pressures.Compared with the bare 2 ×2 rod bundle,the wire-wrapped spacer not only changes the circumferential wall tempera-ture profiles of the heat tube,but also promotes the average heat transfer coefficient.
What problem does this paper attempt to address?