Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality

Chen-Jiang Wu,Qing Wang,Jing Zhang,Xiao-Ning Wang,Xi-Sheng Liu,Yu-Dong Zhang,Hai-Bin Shi
DOI: https://doi.org/10.1007/s00261-015-0615-5
IF: 2.4
2015-01-01
Abdominal Radiology
Abstract:Objective The purpose of this study was to compare the image quality of readout-segmented echo-planar imaging (RS-EPI) and that of standard single-shot echo-planar imaging (SS-EPI) in the kidney in a rat model. Materials and methods Twelve Wistar rats undergoing MRI examinations were imaged with two diffusion-weighted (DW) imaging protocols: a standard SS-EPI and a new RS-EPI protocol, both with a 1.0 × 1.0 × 3.0 mm voxel. The two groups of diffusion-weighted images were independently scored on geometric distortion, image blurring, signal dropout, and the overall image quality by two radiologists. Signal-to-noise ratio (SNR) and apparent diffusion coefficient (ADC) were measured on both sequences. Inter-rater agreement (IRA) was evaluated by Fleiss kappa ( κ ) and inter-class correlation coefficient (ICC) statistics. Comparisons of image qualities were made by Wilcoxon signed-rank test and paired-sample t test. Results Both RS-EPI and SS-EPI had good IRAs in scoring image qualities ( κ = 0.607–0.833) and measuring renal ADCs (ICC = 0.828–0.945). Compared to SS-EPI, RS-EPI produced less geometric distortion (median score 1.5 versus 2.5, p < 0.0001), less image blurring (1.75 versus 2.0, p = 0.0003), less signal dropout (1.0 versus 3.0, p = 0.0001), and a lower score in overall image artifacts (4.25 versus 7.25; p < 0.0001). RS-EPI had higher SNR of renal DW images than SS-EPI ( p < 0.001). The intra-variability of ADCs in cortex, outer medulla, and inner medulla ranged from 9.6 % to 11.1 % (Pearson correlation coefficient ρ = 0.675–0.729; p < 0.001) between the two protocols. Conclusion We showed that for DWI of the kidney at 1.0 × 1.0 × 3.0 mm 3 voxel sizes, the new protocol provided better image quality than standard SS-EPI protocol.
What problem does this paper attempt to address?