PD08-01 STUDY ON THE RELATIONSHIP BETWEEN RENAL ULTRASOUND IMAGE CHARACTERISTICS AND TEMPERATURE DURING RADIOFREQUENCY ABLATION
Linfang Yao,Mengyao Cui,Ming Chen,Wei Wang,Wei Chen,Xingqun Zhao,Hongqian Guo
DOI: https://doi.org/10.1097/ju.0000000000000835.01
2020-01-01
Abstract:You have accessJournal of UrologyKidney Cancer: Localized: Ablative Therapy (PD08)1 Apr 2020PD08-01 STUDY ON THE RELATIONSHIP BETWEEN RENAL ULTRASOUND IMAGE CHARACTERISTICS AND TEMPERATURE DURING RADIOFREQUENCY ABLATION Linfang Yao*, Mengyao Cui, Ming Chen, Wei Wang, Wei Chen, Xingqun Zhao, and Hongqian Guo Linfang Yao*Linfang Yao* More articles by this author , Mengyao CuiMengyao Cui More articles by this author , Ming ChenMing Chen More articles by this author , Wei WangWei Wang More articles by this author , Wei ChenWei Chen More articles by this author , Xingqun ZhaoXingqun Zhao More articles by this author , and Hongqian GuoHongqian Guo More articles by this author View All Author Informationhttps://doi.org/10.1097/JU.0000000000000835.01AboutPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookLinked InTwitterEmail Abstract INTRODUCTION AND OBJECTIVE: To study the noninvasive temperature measurement method in radiofrequency ablation of pig kidney based on B-ultrasound image through exploring the relationship between the characteristic parameters of ultrasound images and temperature. METHODS: The radiofrequency ablation experiment of the kidney was designed and carried out. The experimental system consisted of three modules: radio frequency ablation system, temperature measurement system and ultrasonic measurement system. The experiment used in vitro healthy pig kidney and in vivo healthy pig kidney as biomaterials, and collected B-ultrasound image data and real-time temperature data during radiofrequency ablation. Based on the C++/python and opencv image processing methods, the parameters of image data were obtained and analyzed statistically, which were used as information parameters for the temperature change of the target region. The average gray level-temperature model is used to predict the temperature in the region of the ultrasound video to obtain the 2D pseudo color temperature distribution result. RESULTS: There is a significant positive correlation between the gray mean value, the gray standard deviation of the ultrasound image of the heated tissue and the temperature value during the radiofrequency ablation of the kidney. This relationship can be described by a piecewise function model, the model segmentation point is 65 °C. The model is a linear function when it is less than the segmentation point, and is a quadratic polynomial when it is greater than the segmentation point. The fitting goodness -- R2 of the fitting results obtained by this model is greater than 0.9. CONCLUSIONS: The results of this study preliminarily showed that in the radiofrequency ablation treatment of renal tumors, the mean of gray scale and gray standard deviation of the B-ultrasound images can be used to nondestructively measure the temperature of the tissue. It provides a basis for clinical use of non-destructive temperature measurement based on B-ultrasound image in tumor ablation. Source of Funding: This work was supported by the National Natural Science Foundation of China (Grant No. 81972388, 81772710) , Nanjing health science and technology development special fund project (YKK18076), Jiangsu postdoctoral research fund (1701023B), the Project of Invigorating Health Care through Science, Technology and Education, Jiangsu Provincial Key Medical Discipline (Laboratory) (ZDXKB2016014). © 2020 by American Urological Association Education and Research, Inc.FiguresReferencesRelatedDetails Volume 203Issue Supplement 4April 2020Page: e167-e167 Advertisement Copyright & Permissions© 2020 by American Urological Association Education and Research, Inc.MetricsAuthor Information Linfang Yao* More articles by this author Mengyao Cui More articles by this author Ming Chen More articles by this author Wei Wang More articles by this author Wei Chen More articles by this author Xingqun Zhao More articles by this author Hongqian Guo More articles by this author Expand All Advertisement PDF downloadLoading ...