Reliable Low-Cost Devices for Monitoring Ammonia Concentrations and Emissions in Naturally Ventilated Dairy Barns

Xiang Wang,Pius M. Ndegwa,HungSoo Joo,George M. Neerackal,Joseph H. Harrison,Claudio O. Stoeckle,Heping Liu
DOI: https://doi.org/10.1016/j.envpol.2015.10.031
IF: 8.9
2016-01-01
Environmental Pollution
Abstract:This research investigated the use of two relatively cost-effective devices for determining NH3 concentrations in naturally ventilated (NV) dairy barns including an Ogawa passive sampler (Ogawa) and a passive flux sampler (PFS). These samplers were deployed adjacent to sampling ports of a photoacoustic infrared multigas spectroscope (INNOVA), in a NV dairy barn. A 3-day deployment period was deemed suitable for both passive samplers. The correlations between concentrations determined with the passive samplers and the INNOVA were statistically significant (r = 0.93 for Ogawa and 0.88 for PFS). Compared with reference measurements, Ogawa overestimated NH3 concentrations in the barn by ∼ 14%, while PFS underestimated NH3 concentrations by ∼ 41%. Barn NH3 emission factors per animal unit (20.6-21.2 g d(-1) AU(-1)) based on the two passive samplers, after calibration, were similar to those obtained with the reference method and were within the range of values reported in literature.