Effects of Measuring Position and Management Factor on Ammonia Concentration in Pig House

洪奇华,陆东海,毛国辉,潘倩,陈安国
DOI: https://doi.org/10.3969/j.issn.1673-1182.2008.04.019
2008-01-01
Abstract:Measuring the ammonia concentration is a conventional way to evaluate the environment of pig house or the technique of controlling ammonia.This study is focused on the effects of measuring position and management factor on ammonia concentration in pig house.It is shown that the ammonia concentration is significantly decreased as the raise of testing height as well as the enhancement of aeration and manure cleaning.Furthermore,the concentration is remarkably affected by temperature and humidity,while the regression mode is YNH3=0.560 T + 4.602 RH-8.559(P0.01).