Effects of Pre-Crosslinking on Space Charge and Breakdown Characteristics of XLPE Cable Insulation

Zhenpeng Zhang,You Wu,Chao Fu,Shaoxin Meng,Chao Peng,Zhonglei Li,Boxue Du
DOI: https://doi.org/10.3390/en15072360
IF: 3.2
2022-03-24
Energies
Abstract:This study focused on the effect of pre-crosslinking on the electrical properties of XLPE insulation for HVDC cables. The XLPE samples were pre-crosslinked at 140, 150 and 160 °C. The space charge and DC breakdown characteristics of the XLPE samples with and without pre-crosslinking were investigated. The results show that the pre-crosslinked XLPE samples have an obvious space charge injection and transportation, resulting in more severe electric field distortion. Under the electric field of 100 kV/mm, the electric field distortion rates of the XLPE samples pre-crosslinked at 150 and 160 °C reached 51% and 72% respectively, which were much higher than that of the XLPE sample without pre-crosslinking (14%.) Compared with the XLPE without pre-crosslinking, the breakdown strengths of XLPE pre-crosslinked at 140, 150 and 160 °C were reduced by 11%, 6% and 7% respectively, at the temperature of 50 °C. It is concluded that the pre-crosslinking leads to imperfect crystallization and micro-defects in the amorphous region of XLPE, thereby leading to more space charge accumulation and reduced DC breakdown. The pre-crosslinking of XLPE insulation therefore should be prevented during HVDC cable manufacturing.
energy & fuels
What problem does this paper attempt to address?