Detection of 3-Phenoxybenzoic Acid in River Water with a Colloidal Gold-Based Lateral Flow Immunoassay.

Yuan Liu,Aihua Wu,Jing Hu,Manman Lin,Mengtang Wen,Xiao Zhang,Chongxin Xu,Xiaodan Hu,Jianfeng Zhong,Lingxia Jiao,Yajing Xie,Cunzhen Zhang,Xiangyang Yu,Ying Liang,Xianjin Liu
DOI: https://doi.org/10.1016/j.ab.2015.04.022
IF: 2.9
2015-01-01
Analytical Biochemistry
Abstract:3-Phenoxybenzoic acid (3-PBA) is a general metabolite of synthetic pyrethroids. It could be used as a generic biomarker for multiple pyrethroids exposure for human or pyrethroid residues in the environment. In this study, monoclonal antibodies (mAbs) against 3-PBA were developed by using PBA-bovine serum albumin (BSA) as an immunogen. In the competitive enzyme-linked immunosorbent assay (ELISA) format, the I50 and I10 values of purified mAbs were 0.63 and 0.13 μg/ml, respectively, with a dynamic range between 0.19 and 2.04 μg/ml. Then, the colloidal gold (CG)-based lateral flow immunoassay was established based on the mAbs. The working concentration of coating antigen and CG-labeled antibodies and the blocking effects were investigated to get optimal assay performance. The cutoff value for the assay was 1 μg/ml 3-PBA, and the detection time was within 10 min. A total of 40 river water samples were spiked with 3-PBA at different levels and determined by the lateral flow immunoassay without any sample pretreatments. The negative false rate was 2.5%, and no positive false results were observed at these levels. This lateral flow immunoassay has the potential to be an on-site screening method for monitoring 3-PBA or pyrethroid residues in environmental samples.
What problem does this paper attempt to address?