Usefulness of Two-Point Dixon Fat-Water Separation Technique in Gadoxetic Acid-Enhanced Liver Magnetic Resonance Imaging.

Ying Ding,Sheng-Xiang Rao,Cai-Zhong Chen,Ren-Chen Li,Meng-Su Zeng
DOI: https://doi.org/10.3748/wjg.v21.i16.5017
IF: 5.374
2015-01-01
World Journal of Gastroenterology
Abstract:AIM:To compare differences between volumetric interpolated breath-hold examination (VIBE) using two-point Dixon fat-water separation (Dixon-VIBE) and chemically selective fat saturation (FS-VIBE) with magnetic resonance imaging examination.METHODS:Forty-nine patients were included, who were scanned with two VIBE sequences (Dixon-VIBE and FS-VIBE) in hepatobiliary phase after gadoxetic acid administration. Subjective evaluations including sharpness of tumor, sharpness of vessels, strength and homogeneity of fat suppression, and artifacts that were scored using a 4-point scale. The liver-to-lesion contrast was also calculated and compared.RESULTS:Dixon-VIBE with water reconstruction had significantly higher subjective scores than FS-VIBE in strength and homogeneity of fat suppression (< 0.0001) but lower scores in sharpness of tumor (P < 0.0001), sharpness of vessels (P = 0.0001), and artifacts (P = 0.034). The liver-to-lesion contrast on Dixon-VIBE images was significantly lower than that on FS-VIBE (16.6% ± 9.4% vs 23.9% ± 12.1%, P = 0.0001).CONCLUSION:Dixon-VIBE provides stronger and more homogenous fat suppression than FS-VIBE, while has lower clarity of focal liver lesions in hepatobiliary phase after gadoxetic acid administration.
What problem does this paper attempt to address?