Design of the High-Resolution Soft X-ray Imaging System on the Joint Texas Experimental Tokamak

Jianchao Li,Yonghua Ding,Xiaoqing Zhang,Zhengyu Xiao,Ge Zhuang
DOI: https://doi.org/10.1063/1.4886432
IF: 1.6
2014-01-01
Review of Scientific Instruments
Abstract:A new soft X-ray diagnostic system has been designed on the Joint Texas Experimental Tokamak (J-TEXT) aiming to observe and survey the magnetohydrodynamic (MHD) activities. The system consists of five cameras located at the same toroidal position. Each camera has 16 photodiode elements. Three imaging cameras view the internal plasma region (r/a < 0.7) with a spatial resolution about 2 cm. By tomographic method, heat transport outside from the 1/1 mode X-point during the sawtooth collapse is found. The other two cameras with a higher spatial resolution 1 cm are designed for monitoring local MHD activities respectively in plasma core and boundary.
What problem does this paper attempt to address?