Accuracy of diagnosing gastroesophageal reflux disease by GerdQ, esophageal impedance monitoring and histology.

Li Ya Zhou,Ye Wang,Jing Jing Lu,Lin Lin,Rong Li Cui,He Jun Zhang,Yan Xue,Shi Gang Ding,San Ren Lin
DOI: https://doi.org/10.1111/1751-2980.12135
2014-01-01
Journal of Digestive Diseases
Abstract:Objective To assess the performance of self-assessment gastroesophageal reflux disease questionnaire (GerdQ), 24-h impedance monitoring, proton pump inhibitor (PPI) test and intercellular space of esophageal mucosal epithelial cells in the diagnosis of gastroesophageal reflux disease (GERD). Methods Patients with symptoms suspected of GERD were administered the GerdQ and underwent endoscopy (measurement of intercellular space in the biopsy specimen sampling at 2 cm above the Z-line) and 24-h impedance pH monitoring, together with a 2-week experimental treatment with esomeprazole. Results A total of 636 patients were included for the final analysis, including 352 with GERD. The sensitivity and specificity of GerdQ and 24-h impedance monitoring for diagnosing GERD were 57.7% and 48.9%, and 66.4% and 43.3%, respectively. The sensitivity of 24-h impedance pH monitoring increased to 93.7%. The sensitivity and specificity of dilated intercellular spaces (DIS) (>= 0.9 mu m) for diagnosing GERD were 61.2% and 56.1%, respectively, whereas those for PPI test were 70.5% and 44.4%. Conclusions GerdQ score or PPI test alone cannot accurately diagnose GERD in a Chinese population suspected of GERD. A definitive diagnosis of GERD still depends on endoscopy or 24-h pH monitoring. 24-h impedance pH monitoring may increase the sensitivity for diagnosing GERD by 20%; however, when used alone, it results in poor specificity in patients without acid suppressive therapy.
What problem does this paper attempt to address?