Comparing 3-Hour Ph Monitoring in Esophagus with 24-Hour Ph Monitoring to Diagnose GERD.

Feng Guijian,Zhao Lili,Liu Yulan
2010-01-01
Abstract:BACKGROUND/AIMS:Ambulatory pH monitoring is an invasive method and it would bring some discomfort for patients to wear the probe for prolonged periods. A short time pH monitoring may be more acceptable with high compliance. Our aim is to determine whether analyzing a 3-hour (prandial and postprandial) period from an ambulatory 24-hour pH monitoring in esophagus would be as sensitive as the routine test.METHODOLOGY:Patients had been called for esophageal manometry and ambulatory 24-hour pH monitoring. 3-hour data were analyzed from the standard ambulatory 24-hour pH recording. GERD was confirmed if pH was less than 4.0 for more than 4% of 24 hours, the data were then reanalyzed by determining the percent time of pH < 4.0 during a 3-hour period. Kappa test and Mc-nemar test were used in the study.RESULTS:Two hundred twenty-one patients met the entrance criterion. The 3-hour test had a sensitivity of 86% when compared to the 24-hour test and a specificity of 84%. Kappa test and Mc-nemar test verified the two monitor periods were considerable consistency.CONCLUSION:3-hour analysis is sensitive and specific test for demonstrating GERD. By using this test, patients can suffer less discomfort and appear enhanced compliance.
What problem does this paper attempt to address?