SEGMENTATION OF INTERFACE PRESSURE MAPS : THE USE OF A CONNECTED ELLIPSE MODEL TO IDENTIFY AREAS AT RISK FOR PRESSURE ULCER DEVELOPMENT
Brittany N. Neilson,J. C. Brill
Abstract:S 39 Biomedical and General Engineering DIFFERENTIATING MANIFESTATIONS OF SOPITE SYNDROME AS PRODUCED BY INERTIAL MOTION AND VECTION. Brittany N. Neilson & J. Christopher Brill, Department of Psychology, Old Dominion University, Norfolk VA 23529. Sopite syndrome is a polysymptomatic manifestation of motion sickness that presents itself as marked drowsiness despite receiving an adequate night’s sleep, relaxation, and lack of motivation. Previous studies evaluate sopite syndrome using either a motion device or a vection device. The present research aims to differentiate the symptoms of sopite syndrome produced by actual motion versus perceived self-motion (i.e., vection) in order to better identify the psychophysiological markers of sopite syndrome. Twenty-five undergraduate psychology students participated in the pilot study. An analysis of covariance was used to evaluate participant’s self-reports on motion questionnaires, physiological measurements, and brain activity across three motion conditions (inertial motion, vection, and control) holding traits of sleepiness and motion sickness constant. Participants in the motion condition reported increased symptoms (M = 20.75, SD = 23.95) compared to participants in the vection (M = 8.53, SD = 25.45) and control conditions (M = 5.53, SE = 24.25), but this effect was not statistically significant at p < .05, F(2, 19) = 2.87, p = .081, η = .20, due to insufficient sample size. Implications for future research will be discussed. SEGMENTATION OF INTERFACE PRESSURE MAPS: THE USE OF A CONNECTED ELLIPSE MODEL TO IDENTIFY AREAS AT RISK FOR PRESSURE ULCER DEVELOPMENT. Anathea A. Pepperl and Paul A. Wetzel, Department of Biomedical Engineering, Virginia Commonwealth University, Richmond, VA 23284. Mary Jo Grap, Department of Adult Health and Nursing Systems, Virginia Commonwealth University, Richmond, VA 23298. In order to study pressure ulcer development, it is useful to analyze pressures at specific high-risk areas, or regions of interest (ROIs). A contour-based connected ellipse model was used to segment ROIs. A user selected the approximate centers of ROIs. An Expectation-Maximization algorithm refined the center locations and defined an ellipse at each ROI. The connected ellipse model was then iteratively refined so as to minimize (1) the distance between connected ellipses and (2) the distance between the image contour and the edge of the closest ellipse. Ten pressure images were collected from four patients in intensive care units at the Virginia Commonwealth University Health System (VCUHS). The distance between ROI peak pressures generated by automatic and manual segmentations was defined as the error. The average errors (in inches) for each ROI were: 6.64, left scapula; 7.76, right scapula; 4.54, left trochanter; 5.31, right trochanter; 0, left heel; 0.85, right heel. The average error was 4.18 inches. Visual inspection showed that this error was caused by the peak pressure lying just beyond the contour of the ellipse. The connected ellipse model is an effective method for segmenting pressure images. The model may be further refined through the inclusion of intensity data. Virginia Journal of Science, Vol. 62, No. 1, 2011 http://digitalcommons.odu.edu/vjs/vol62/iss1 VIRGINIA JOURNAL OF SCIENCE 40 DEVELOPMENT OF A NOVEL BLOOD ANALOG WITH PHYSIOLOGICAL SHEAR-THINNING AND VISCOSITY CHARACTERISTICS. S. J. Warren, C. E. Taylor, and G. E. Miller, Dept. Biomedical Engineering, VCU. Mock loops are a integral part of the testing and evaluation of cardiac assist devic. In order to obtain near physiological data in a mock circulatory loop, a compressive fluid similar to human blood is needed. This project will test the properties of an oil base fluid, in order to match the viscoelastic properties of Human blood. The work presented was based on the following research questions: Does the oil based fluid show shear thinning properties closest to those of human whole blood? Does the oil based fluid correlate with the viscoelastic curve of human whole blood better than other blood analogs currently in use? All viscosity data was collected on an Anton Paar Rheometer with a parallel plate and 500 micron gap. The test was a shear sweep from .001 to 1000 1/s. The work presented two candidates; one that is optical clear and the other is rheological more accurate. The components are pure and commercially validated for mechanical properties, which releases the end user from having to revalidate the constructed solution. Choice of fluid construction was designed to prevent large dilution factors, to provide a robust method for fabricated a shear-thinning blood analog for cardiac assist device evaluation. CONTROL MODEL AND PERFORMANCE OF A COMPLIANCE CHAMBER FOR SIMULATING ARTERIAL SYSTEMIC COMPLIANCE. C. E. Taylor and G. E. Miller, Dept. of Biomedical Engineering, VCU. Utilizing mock circulatory loops as a bench test method for cardiac assist technologies provides that the system must be capable of reproducing the circulatory conditions that would exist physiologically. Of particular interest is the ability to determine compliance delivered by the system, and the ability to change the compliance in real-time. The latter capability allows for continuous battery testing of conditions without stopping the loop operation when changing the compliance chamber settings. The compliance chamber presented utilizes a natural latex rubber membrane separating the fluid and air portions of the device. Change in system compliance is affected by the airspace pressure, which creates more reaction force at the membrane to the fluid pressure. A pressure sensor in the fluid portion of the chamber and a displacement sensor monitoring membrane position allow for real-time inputs to the control algorithm. A predefined numerical model correlates the displacement sensor data to the volume distention of the membrane. The PI controller tuning was achieved by creating a computational model of the compliance chamber using Simulink Simscape toolboxes. It was found that the resulting control architecture was capable of maintaining a compliance set point, and allowed for changes to the compliance without stopping the pulsatile flow of the mock circulatory loop. THE EVOLUTION OF AN EVENT DETECTION ALGORITHM. Pallavi Ramnarain and Dr. Paul A. Wetzel, Dept. of Biomedical Engineering, Virginia Commonwealth University, Richmond, VA. The purpose of this presentation was to explore the methodological processes behind the development of event detection algorithms. Signal acquisition imposes the first set of limitations on event detection. After that an iterative process is initiated. The first step is to identify the event of interest. Then it must be defined using finite, quantitative characteristics that Virginia Journal of Science, Vol. 62, No. 1, 2011 http://digitalcommons.odu.edu/vjs/vol62/iss1