Adsorption of Carbon Dioxide by MIL-101(Cr): Regeneration Conditions and Influence of Flue Gas Contaminants

Qing Liu,Liqi Ning,Shudong Zheng,Mengna Tao,Yao Shi,Yi He
DOI: https://doi.org/10.1038/srep02916
IF: 4.6
2013-01-01
Scientific Reports
Abstract:MIL-101(Cr) has drawn much attention due to its high stability compared with other metal-organic frameworks. In this study, three trace flue gas contaminants (H 2 O, NO, SO 2 ) were each added to a 10 vol% CO 2 /N 2 feed flow and found to have a minimal impact on the adsorption capacity of CO 2 . In dynamic CO 2 regeneration experiments, complete regeneration occurred in 10 min at 328 K for temperature swing adsorption-N 2 -stripping under a 50 cm 3 /min N 2 flow and at 348 K for vacuum-temperature swing adsorption at 20 KPa. Almost 99% of the pre-regeneration adsorption capacity was preserved after 5 cycles of adsorption/desorption under a gas flow of 10 vol% CO 2 , 100 ppm SO 2 , 100 ppm NO and 10% RH, respectively. Strong resistance to flue gas contaminants, mild recovery conditions and excellent recycling efficiency make MIL-101(Cr) an attractive adsorbent support for CO 2 capture.
What problem does this paper attempt to address?