A Proximal Entry Tear Located in the Proximal Trunk of the Left Subclavian Artery is Confirmed by Balloon Inflation Blocking and Sealed with an Occluder

Wang Li-xin,Guo Da-qiao,Shi Zhen-yu,Tang Xiao,Fu Wei-guo
DOI: https://doi.org/10.3760/cma.j.issn.0366-6999.20122470
IF: 6.133
2013-01-01
Chinese Medical Journal
Abstract:Aortic dissection (AD) is a catastrophic disease involving the aorta. Most intimal tears are located in the ascending aorta or the first portion of the descending aorta.1 It is a rare case that the proximal tear originates from the left subclavian artery (LSA). Virtual endoscopy (VE) technology could provide us a specific perspective to see from intraluminal to the outside and was especially helpful to look for and indentify complicated intimal tears.2 Vascular occluder is a useful device to treat vessel diseases alone or combined with other appratus.3 In the present report, we described one case of type B AD with a proximal tear located at the root of LSA. This tear was indentified by VE, confirmed by balloon inflation blocking and sealed with an occluder, while the second tear was repaired with one stent graft (SG). A 60-year-old male patient was admitted to our hospital because of sudden onset of acute thoracic and back pain for one day. Computer tomography (CT) scan demonstrated that the dissection was formed in the descending aorta (Figure 1A and 1B). VE reconstruction revealed that the proximal tear located just in the root of LSA (Figure 1C). Cross-sectional image showed the second tear located in the middle part of the descending aorta (Figure 1D). Physical examination revealed that the artery pulse of the lower extremity was compromised while the upper one was normal. On admission, his blood pressure (BP) was as high as 210/130 mmHg (1 mmHg=0.133 kPa). Though sufficient oral and intravenous anti-hypertension drugs were administrated, his BP remains as high as 160/100 mmHg. After 2 days of treatment with anti-hypertension and analgesic drugs, he complained the pain was still severe and continuous. For this reason, we decide to treat his lesion with an endovascular method immediately.Figure 1.: Pre-operative contrast enhanced computed tomography. A: Three dimensional reconstruction showed that the LSA was comprised of the dissection. B and C: Longitudinal section and cross-section of the thoracic aorta hard to tell the exact location of the proximal tear. D: Virtual endoscopy showed the anatomical relationship between LSA, proximal tear, FL, TL, and septum.After general anesthesia, the right common femoral artery was exposed and punctured by Seldinger method. A carotid and vertebral artery angiogram displayed that the right vertebral artery (RVA) was the dominant one while the Willis circle was complete (Figure 2A). An arch angiogram showed that the proximal tear was near the orifice of the LSA (Figure 2B) while the true lumen (TL) was severely compressed by false lumen (FL). But it was hard to tell whether the proximal tear was directly from the arch or the root of the LSA. We put a PTA balloon (P3, 8 mm × 40 mm, Cordis, Spain) from the brachial artery to the root of LSA. After balloon inflation, an aorta angiogram revealed that the proximal tear had disappeared and the FL was only showed slowly in a delayed phase (Figure 2C). The distance between the second tear and LSA is about 12 cm. Then an occluder (10 mm × 20 mm, Lifetech. Scientific, China) was placed in the proximal part of LSA through a 9F sheath. The 3rd arch angiogram displayed that the proximal tear was thoroughly sealed (Figure 2D). Then, one SG (Zenith, 38 mm × 200 mm, Cook, USA) was deployed in the descending aorta to seal the second tear and expand the TL. The last aorta angiogram demonstrated that the FL completely vanished, the TL expanded and a short of SG protruded into the FL (Figure 2E). After endovascular therapy, the patient's pain was completely relieved and his BP gradually returned to normal range with the help of antihypertensive drugs. He recovered uneventfully and was discharged 3 days later. BP difference between two upper extremities is about 30/15 mmHg. He denied any dizziness or hand numbness after left upper extremity exertion. Six months’ follow-up CT scan displayed perfect positioning of the occluder with complete obliteration of the proximal tear, complete thrombosis was formed in the FL of thoracic segment.Figure 2.: Intra-operative angiogram. A: Carotid-vertebral artery and Wills circle angiogram showed that the right vertebral artery is dominating and the Willis circle is complete. B: The 45 degree left anterior oblique angiogram showed that the proximal tear located near the trunk of LSA, but hard to exclude the possibility that it origin from the ceiling of the arch near LSA. C: Balloon was used to check the exact location of the first entry tear. D: The first entry tear was sealed with an occluder placed in LSA. E: One SG was deployed in the descending aorta to repair the second tear.AD is a catastrophic disease with a high fatality rate. Endovascular SG placement has been emerging as an effective and less invasive treatment for complicated type B AD. We treated this patient in the subacute stage for his pain, which remained severe and his BP was hard to control. Commonly, the proximal tear of type B AD is directly located in the aorta distal to the orifice of LSA.1 Most information about the exact location of the proximal and distal tear of a type B AD could been obtained from contrast enhanced CT scan and 3D reconstruction. But for this patient, the preoperation CT demonstrated the proximal tear just near the origin of LSA but failed to exhibit the exact position. VE is an advancement of CT diagnostic technology and could afford us a specific perspective to see from intraluminal to the outside.2 Pre-operative VE image of this patient prompted that the proximal tear was located in the root of LSA but was not clear and affirmative enough. The intra-operative angiogram showed that CM not only went through the proximal tear near the LSA, but also failed to discriminate whether it was located in the proximal part of the LSA or the arch. In order to validate the information from preoperative VE image and arch angiogram, a PTA balloon was forwarded through the brachial artery. The angiogram after balloon inflation blocking showed that this tear was obliterated. This phenomenon confirmed what we know from VE that the proximal entry tear was located in the root of LSA. The question that followed was how to seal this tear? If only one SG to occlude the orifice of LSA was deployed, the direct forward blood flow from LSA to FL could be stopped, however, the perfusion of the FL would be substituted by the back flow from the left vertebral artery (LVA). An occluder can seal the first tear and prevent retrograde blood flow from the LVA as we tested before. As to this patient, for the RVA is the dominant one and Willis circle is complete, we need not worry about the ischemia of posterior circulation. If the patient finally suffered from severe upper limb ischemia, left carotid artery (LCA) to LSA bypass could be done at a later stage to restore blood supply. Deploying one small SG like wall-graft or fluency into LSA is also a feasible alternative to seal this proximal tear. Its superiority lies in the reservation of blood supply of LSA and LVA and this is extremely useful when the patient has the contraindication to cover LSA. However, the wall-graft SG has the problem of relatively poor apposition while the fluency is too rigid and these will result in potential endoleak. Another applicable way is to ligate LSA combined with a LCA to LSA bypass or not by open surgery. However, this is a traumatic process and may expose patients to a risk of mortality and complications. After placement of one occluder, the angiogram then displayed that the second tear located in the middle part of the aorta and TL was compressed. So we deployed one SG to seal this second tear and expand the TL. Follow-up CT demonstrate optimal position of the occluder, absence of endoleak, complete FL thrombosis in the thoracic segment, expansion of the TL, and shrinkage of the false one. Aortic dissection originating from LSA has a very low incidence. High quality preoperation CTA with adequate reconstructions including VE is very helpful in these cases to tell the exact position of the proximal tear. It's an applicable and feasible way to identify and seal this entry tear with balloon occlusion and occluder placement.
What problem does this paper attempt to address?