First in man: blocking the false lumen backflow of aortic dissection after thoracic endovascular aortic repair by an off-the-shelf EndoSealTM system

Yangyang Ge,Hongpeng Zhang,Wei Guo
DOI: https://doi.org/10.1093/eurheartj/ehae117
IF: 39.3
2024-03-02
European Heart Journal
Abstract:A 58-year-old male, who underwent thoracic endovascular aortic repair (TEVAR) for type B aortic dissection ten years ago, presented with persistent dull back pain over the past 6 months. Computed tomographic angiography (CTA) showed a gradient of opacified blood in the thoracic false lumen (white arrows in Panel A ) and a maximum diameter of 53.8 mm ( Panel B ). Intraoperative angiography confirmed the thoracic false lumen backflow ( Panel C ).