Performance of a novel up-flow electrocatalytic hydrolysis acidification reactor (UEHAR) coupled with anoxic/oxic system for treating coking wastewater
Jian Dong,Zhaobo Chen,Fei Han,Dongxue Hu,Hui Ge,Bei Jiang,Jitao Yan,Shuya Zhuang,Yifan Wang,Shiming Cui,Zhibo Liang
DOI: https://doi.org/10.1016/j.watres.2024.121670
IF: 12.8
2024-04-27
Water Research
Abstract:In this study, the performance of a novel up-flow electrocatalytic hydrolytic acidification reactor (UEHAR) and anoxic/oxic (ANO 2 /O 2 ) combined system (S 2 ) was compared with that of a traditional anaerobic/anoxic/oxic (ANA/ANO 1 /O 1 ) system (S 1 ) for treating coking wastewater at different hydraulic retention time (HRT). The effluent non-compliance rates of chemical oxygen demand (COD) of S 2 were 45%, 35%, 25% and 55% lower than S 1 with HRT of 94, 76, 65 and 54h. The removal efficiency of benzene, toluene, ethylbenzene and xylene (BTEX) in S 2 was 10.6±2.4% higher than that in S 1 . The effluent concentration of Volatile phenolic compounds (VPs) in S 2 was lower than 0.3mg/L. The dehydrogenase activity (DHA) and adenosine triphosphate (ATP) of O 2 were enhanced by 67.2±26.3% and 40.6±14.2% compared with O 1 , respectively. Moreover, COD was used to reflect the mineralization index of organic matter, and the positive correlation between COD removal rate and microbial activity, VPs, and BTEX was determined. These results indicated that S 2 had extraordinary microbial activity, stable pollutant removal ability, and transcendental effluent compliance rate.
environmental sciences,engineering, environmental,water resources