Determination of Acidic Herbicides in Surface Water by Solid-Phase Extraction Followed by Capillary Zone Electrophoresis.

Wd Qin,Hp Wei,Sfy Li
DOI: https://doi.org/10.1093/chromsci/40.7.387
2002-01-01
Journal of Chromatographic Science
Abstract:A rapid solid-phase extraction-capillary zone electrophoresis (CZE) method for determining 2,4-dichlorophenoxyacetic acid, 4-(2,4-dichlorophenoxy) butyric acid, and 2,4,5-trichlorophenoxyacetic acid in real water samples is described. Factors affecting the recoveries and detection of the targets are investigated. With samples being acidified to pH 2 and salted by sodium sulfate to 2% (w/w), an average recovery of greater than 85% is obtained using ethyl acetate as the eluent on an octadecylsilane-bonded silica cartridge. A running buffer of 5 mM sodium tetraborate in a water-acetonitrile mixture (70:30, v/v) adjusted to pH 9 is employed in the CZE analysis, and the targets can be analyzed within 7 min with good reproducibility and acceptable sensitivity. The method is suitable for detecting herbicide residues of sub-parts-per-billion levels in surface water. A local pond water is analyzed, and the concentrations of 2,4-dichlorophenoxyacetic acid and 4-(2,4-dichlorophenoxy) butyric acid are detected to be 0.27 +/- 0.03 ppb and 0.61 +/- 0.08 ppb, respectively.