BIODEGRADABLE POLYMER VERSUS PERMANENT POLYMER SIROLIMUS-ELUTING STENTS IN UNSELECTED PATIENTS WITH ST-SEGMENT ELEVATION MYOCARDIAL INFARCTION UNDERGOING PRIMARY PERCUTANEOUS CORONARY INTERVENTION

Feng Zhang,Yuhua Zheng,Juying Qian,Junbo Ge
DOI: https://doi.org/10.1016/j.ijcard.2012.04.056
IF: 24
2012-01-01
Journal of the American College of Cardiology
Abstract:The permanent polymers coated on the drug-eluting stent (DES) seem to play a central role in perpetuating local vascular inflammatory reaction and potentially inducing the occurrence of late and very late stent thrombosis. Therefore, the concept of a polymer that carries and controls the drug release during a proper period of time and after that erodes and vanishes from the vascular surface seems to be an attractive technology for improved safety and efficacy. Recently, several novel DES with biodegradable polymers have been developed, mainly to improve long-term DES safety [ 1 Ge J. Qian J. Wang X. Wang Q. Yan W. Yan Y. et al. Effectiveness and safety of the sirolimus-eluting stents coated with bioabsorbable polymer coating in human coronary arteries. Catheter Cardiovasc Interv. 2007; 69: 198-202 Crossref PubMed Scopus (41) Google Scholar , 2 Windecker S. Serruys P.W. Wandel S. Buszman P. Trznadel S. Linke A. et al. Biolimus-eluting stent with biodegradable polymer versus sirolimus-eluting stent with durable polymer for coronary revascularisation (LEADERS): a randomised non-inferiority trial. Lancet. 2008; 372: 1163-1173 Abstract Full Text Full Text PDF PubMed Scopus (596) Google Scholar , 3 Byrne R.A. Kastrati A. Kufner S. Massberg S. Birkmeier K.A. Laugwitz K.L. et al. Intracoronary Stenting and Angiographic Results: Test Efficacy of 3 Limus-Eluting Stents (ISAR-TEST-4) Investigators. Randomized, non-inferiority trial of three limus agent-eluting stents with different polymer coatings: the Intracoronary Stenting And Angiographic Results: Test Efficacy of 3 Limus-Eluting Stents (ISAR-TEST-4) Trial. Eur Heart J. 2009; 30: 2441-2449 Crossref PubMed Scopus (203) Google Scholar , 4 Tin Hay E. Hou X.M. Lim J. Low A. Teo S.G. Tan H.C. et al. A novel drug-eluting stent using bioabsorbable polymer technology: two-year follow-up of the CURAMI registry. Int J Cardiol. 2009; 131: 272-274 Abstract Full Text Full Text PDF PubMed Scopus (7) Google Scholar , 5 Davlouros P.A. Mavronasiou E. Xanthopoulou I. Karantalis V. Tsigkas G. Hahalis G. et al. An optical coherence tomography study of two new generation stents with biodegradable polymer carrier, eluting paclitaxel vs. biolimus-A9. Int J Cardiol. 2011 Jan 8; ([Epub ahead of print]) Google Scholar ]. Nevertheless, little specific information is available regarding the use of these new devices in a high risk subset of patients with acute myocardial infarction (MI). The present study aimed to compare the safety and efficacy of the Excel biodegradable polymer sirolimus-eluting stent (BP-SES) (JW Medical, Weihai, China) with the permanent polymer SES (PP-SES) in primary percutaneous coronary intervention (PCI) for unselected patients with ST-segment elevation MI (STEMI).
What problem does this paper attempt to address?