Study of Energy Flow Mechanisms in High Power Device Converters

Zheyuan Zhao,Qianzheng Jin,Yingjie Wu,Gen Li,Tiange Xiang
DOI: https://doi.org/10.3390/en17081980
IF: 3.2
2024-04-23
Energies
Abstract:The work in this paper is applied to the Zhangbei Power grid. In the flexible direct current (DC) power system, the fault current rises extremely fast when a DC fault occurs. The requirements for the peak of breaking current and fault energy absorption of DC circuit breakers (DCCBs) increase linearly, which significantly increases the cost of the equipment. Therefore, in order to reduce the design difficulty of DCCBs, this paper proposes a strategy to control energy after the fault occurs. Firstly, the energy dimension is added on the basis of the traditional vector control of MMC, which constitutes a three-dimensional energy direct control. Subsequently, the architectures of energy fluctuation control and feedforward control are proposed. The influencing mechanisms for the peak fault current, peak fault voltage and energy dissipation are analyzed. Finally, the simulation of energy fluctuation control and feedforward control is constructed on PSCAD/EMTDC. The simulation results show that the energy fluctuation control is obviously better than the conventional three-dimensional energy control, and the feedforward energy control is further improved on this basis. Compared with the conventional vector control, the peak energy is reduced by 45.43% and the peak current is reduced by 25.39%, which helps to simplify the equipment design and reduce the equipment cost.
energy & fuels
What problem does this paper attempt to address?
### Problems Addressed by the Paper The paper primarily addresses the issue of DC faults in Modular Multilevel Converter-based High Voltage Direct Current (MMC-HVDC) systems and proposes a new energy control strategy to reduce the peak current and energy absorption requirements of DC Circuit Breakers (DCCB) during faults. Specifically: 1. **Background Issues**: - In flexible DC transmission systems, when a DC fault occurs, the fault current rises rapidly, which significantly increases the requirements for the peak current interruption capability and fault energy absorption capacity of DC circuit breakers. - These increased requirements not only raise the cost of equipment but also add to the design complexity. 2. **Research Objectives**: - Propose an energy control strategy that adds an energy dimension to traditional vector control to achieve three-dimensional direct energy control. - Design energy fluctuation control and feedforward control architectures, and analyze the impact mechanisms of these control strategies on peak fault current, peak fault voltage, and energy dissipation. - Validate the effectiveness and feasibility of these control strategies through simulations, particularly in comparison to traditional vector control, to see if they can significantly reduce peak energy and peak current. 3. **Specific Methods**: - **Energy Fluctuation Control**: Reduce energy fluctuations during faults by controlling the energy of submodule capacitors. - **Feedforward Control**: Further optimize energy control by adding feedforward signals to reduce the energy of submodule capacitors. 4. **Expected Outcomes**: - Compared to traditional vector control, energy fluctuation control can reduce peak energy by 45.43% and peak current by 25.39%. - Feedforward control further optimizes on this basis, helping to simplify equipment design and reduce costs. ### Summary The paper aims to address the high costs and design difficulties caused by DC faults in flexible DC transmission systems by proposing new energy control strategies, thereby improving the reliability and economic efficiency of the system.