Power Factor Correction Of A 400kw Winding Rotor Induction Motor

Cp Deng,Zb Ling,Ps Ye
DOI: https://doi.org/10.1109/PEDS.2003.1283213
2003-01-01
Abstract:A way of power factor correction of high power winding rotor induction motor is proposed. By using a voltage source with series connection to the rotor of induction motor, the unity power factor can be obtained. A single phase to three phases cycloconverter to realize this voltage source is designed. PSPICE simulation is performed to confirm the correction operation of control strategy. A prototype of a 400kW induction motor was developed, the results confirm the validity of the analysis. The power factor of induction motor reaches 0.97.
What problem does this paper attempt to address?