Clinical Outcomes of Descemet Membrane Endothelial Keratoplasty Using Eye Bank-Prepared Tissues.

Sophie X. Deng,P. James Sanchez,Luxia Chen
DOI: https://doi.org/10.1016/j.ajo.2014.12.007
IF: 5.488
2014-01-01
American Journal of Ophthalmology
Abstract:PURPOSE: To investigate the outcomes of Descemet membrane endothelial keratoplasty (DMEK) using prestripped donor tissue prepared by an eye bank.DESIGN: Retrospective, noncomparative case series.METHODS: This retrospective, noncomparative, observational study investigated the outcomes of the first 40 consecutive DMEK procedures performed by a single surgeon using prestripped tissues prepared by a single eye bank during the period September 17, 2013 to July 1, 2014. A new technique to unfold the Descemet membrane grafts using a single cannula was described. Medical records were reviewed to obtain the prestripped and poststripped endothelial cell counts (ECC), postoperative ECC, visual acuity measurements, and complications.RESULTS: Of the 43 prestripped tissues received, 40 were transplanted. The leading indications for DMEK were Fuchs endothelial corneal dystrophy (n = 28) and bullous keratopathy (n = 11). Nine DMEK procedures were performed in combination with phacoemulsification and posterior chamber intraocular lens implantation. Six patients had undergone prior glaucoma surgeries. The mean follow-up duration was 5.3 months (range, 1 week to 11 months). Preoperative spectacle-corrected visual acuity was <= 20/200 in 8 patients (20%) and <= 20/40 in 37 patients (92.5%). Primary graft failure occurred in the first case. Thirty-eight patients had improved vision postoperatively. Among the 39 patients who had successful DMEK, postoperative BCVA was >= 20/20 in 20 patients (51.2%), >= 20/25 in 30 patients (76.9%), and >= 20/40 in 34 patients (87.2%) by the last follow-up. There was no secondary graft failure. Rejection occurred in 2 patients because of self-discontinuation, of topical corticosteroid. The most common complication was partial detachment requiring air injection (11 of 40 patients; 27.5%). Mean ECC loss after stripping of Descemet membrane was 3.9% (range, 6.5% gain to 14.5% loss). During the first 6 months after transplantation, the average ECC loss was 30.5% (range, 3.8%-67.4% loss).CONCLUSIONS: DMEK using eye bank prepared tissue achieved outcomes comparable to those reported for DMEK using surgeon-prepared tissue. Published by Elsevier Inc. This is an open access article under the CC BY-NC-ND license
What problem does this paper attempt to address?