Simulation of ECR Startup and Comparison with Experimental Observations in SUNIST

Tan Yi,Gao Zhe,Wang Long
DOI: https://doi.org/10.1088/1009-0630/13/1/07
2011-01-01
Abstract:Transient process of ECR startup in SUNIST is analyzed and simulated in a onedimensionalmodel.Contributions from the generation,drift,diffusion and loss of electrons aretaken into account in the model and estimated from experimental parameters,e.g.,toroidal field,vertical field and gas filling pressure.Typical discharges are simulated with the conditions closeto the experimental ones.Experimental and simulated results are comparable qualitatively inamplitudes and semi-quantitatively in time.From the results it is confirmed that the transientprocess of ECR startup in SUNIST is dominated,as preliminarily deduced from experimentalobservations,by a pair of exclusive factors,namely the absorption,due to gas ionization,and thereflection of microwave,caused by the shift of over dense plasmas due to outward E×B drift.Inaddition to these two factors,electron loss along the field line is also very important in determiningthe character of discharges.
What problem does this paper attempt to address?