A Broad W-band Detector Utilizing Zero-Bias Direct Detection Circuitry

Kaida Xu,Yonghong Zhang,Linli Xie,Yong Fan
DOI: https://doi.org/10.1109/iccps.2011.6092273
2011-01-01
Abstract:In this paper, a broad W-band detector utilizing zero-bias direct detection planar circuitry with high voltage sensitivity and enhanced tangential signal sensitivity (TSS) is proposed, which is intended to apply for W-band radiometer. The commercially available GaAs detector diode Agilent® HSCH-9161 is adopted to build an unamplified zero-bias direct detector, along with probe transition, broad band microstrip impedance matching network and low pass filter. Voltage sensitivity up to 1000 mV/mW from 75 GHz to 104.5 GHz (almost full W-band) is achieved. A self-manufactured video amplifier is used to set the video bandwidth (VBW) as approximately 70 Hz and the obtained TSS is better than -51 dBm in the full W-band. The whole circuit is based on microstrip circuits and is hence easy and cheap to fabricate, which satisfies the low cost requirements of assembling large passive millimeter wave imaging array.
What problem does this paper attempt to address?