Effect of the Vane Angle for Outer Secondary Air on the Flow and Combustion Characteristics and NO X Emissions of the Low-NO X Axial-Swirl Coal Burner

Lingyan Zeng,Zhengqi Li,Guangbo Zhao,Shanping Shen,Fucheng Zhang
DOI: https://doi.org/10.1080/10407782.2010.523326
2011-01-01
Numerical Heat Transfer Part A Applications
Abstract:We conducted a cold air experiment and numerical simulation to investigate flow and combustion characteristics and NOx emission of a low-NOx axial-swirl burner in a 600 MWe bituminous coal-burning boiler. Comparison of single-phase numerical simulation results and measurements made by a probe with hot-film sensors shows that the numerical model is a reasonable description. By changing the vane angle for outer secondary air, we obtain different results for the recirculation zone, the divergence angle, the distance that the recirculation zone extends into the burner, the mass of the flue gas that returns to the burner, the temperature of the furnace, and the concentration of NOx emission. The best vane angle for the outer secondary air is determined to be 15 degrees.
What problem does this paper attempt to address?