Experimental Study on the Effect of Alternating‐current Amplitude on GMI Output Stability of Co‐based Amorphous Wires

Jian-Fei Sun,Jing-Shun Liu,Da-Wei Xing,Xiang Xue
DOI: https://doi.org/10.1002/pssa.201026676
2011-01-01
Abstract:The effect of alternating-current amplitude (ACA) on the giant magnetoimpedance (GMI) output stability of Co-based amorphous wires is studied for highly sensitive sensor applications using a precision impedance analyzer placed in a magnetically shielded space. Experimental results indicated that the "spike" phenomenon is related to the inhomogeneous distribution of local critical magnetic fields at a lower ACA, and the GMI output stability of wires can be significantly enhanced by increasing the ACA applied by more than 15 mA. The dependencies of the maximum GMI ratio [Delta Z/Z(0)](max) and magnetic field sensitivity xi(max) on the frequency at I-AC = 15mA have been observed: [Delta Z/Z(0)](max) has a maximum value of 117.32% at 15 MHz, and the corresponding GMI peak position H-p tends to be the saturation of 1 Oe until 12 MHz, and xi(max) has the maximum of 248.34%/Oe at 12 MHz. An applied ACA of 15mA and a working frequency of 12MHz are therefore recommended for the circuit design of a high-resolution magnetic-field sensor. (c) 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim