Analysis of flow characteristic of multi-compound gear pump

于红英,王慧敏,钟汉田
2011-01-01
Abstract:To minish the pulsation coefficient of flow rate of a gear pump, a multi-compound gear pump is studied. By the analysis method of displacement of mesh point, the flow charateristic of multi-compound gear pump is analyzed, and that expression of transient flow rate and general formula of pulsation coefficient of flow rate are deduced. The analysis result shows that the pulsation coefficient of flow rate is minimal and the flow charateristic is the best when z1 = kN + 1 (k is an odd number). Taking an example from three-compound gear pump, its transient flow rate is simulated, which shows that the general formula of pulsation coefficient of flow rate is right.
What problem does this paper attempt to address?