Experimental research on thermal performance of thermal circulatory aerial heated kang of rural residence in severe cold regions

GuiWen Li,Hongguo Ren,XiuMu Fang
2011-01-01
Abstract:To make the heated kang facility better satisfy the demands for indoor heat comfort in rural buildings of severe cold areas in winter, this paper ameliorates the current aerial heated kang into the thermal circulatory aerial heated kang and tests its thermal properties. It tests and records the flue gas composition, inlet flue gas temperature, exit flue gas temperature, flue gas weight, heated kang surface temperature and indoor temperature etc of thermal circulatory aerial heated kang through Testo flue gas analyzer, BES-C portable microcomputer multi-channel data acquisition meter and thermal infrared imager etc in accordance with the selected positive balance measuring approach to figure up the values such as the temperature standard deviation on the heated kang surface, the thermal inertia and the thermal efficiency of the heated kang and consider the thermal properties of thermal circulatory aerial heated kang. It proves the temperature standard deviation on the surface of the thermal circulatory aerial heated kang is 15°C, the thermal storage coefficient is 10.473 and the thermal efficiency is 57.5%.
What problem does this paper attempt to address?