Bandpass Active Filter Designed for Rapid Unbalance Measurement

ZENG Sheng,REN Yi,LI Chang-pin,JIN Tao
DOI: https://doi.org/10.3969/j.issn.1000-3835.2011.06.008
2011-01-01
Abstract:In connection with the efficiency request of the unbalance measurement in automatic rotor balancing machine,an 8th-order band-pass active filter was designed and compared experimentally with a 2nd-order low-pass active filter and a narrow band-pass tracing filter.The result demonstrates that the 2nd-order low-pass active filter is of high measuring accuracy in the case of majority of sampling loops,which may be used in high accuracy requirement situations while the measurement efficiency is not so important.The repeatability accuracy of the narrow band-pass tracing filter is low,so it can only be used in the general balancing machine.In comparison,the 8th-order band-pass active filter is of high measuring accuracy,high repeatability and high efficiency,which can meet the measurement requirement of amplitude 3mg,phase ±1° and measurement time 5 seconds.
What problem does this paper attempt to address?