Experimental Study on Seismic Behavior of Large Grid Size RC Shear Walls

ZHANG Weijing,DU Yinan,KANG Hongzhen,QIAN Jiaru,FENG Baochun
DOI: https://doi.org/10.14006/j.jzjgxb.2011.05.016
2011-01-01
Abstract:To meet the requirement of reinforced concrete(RC) grillage shear wall residence buildings of 6-story or less,the grillage shear wall with grid size of 400mm×400mm,which is called large grid size shear wall,has been developed.Quasi-static tests on two specimens with shear span ratio of 2.02 and two specimens with shear span ratio of 1.13 were carried out to study the seismic behavior,such as failure mode,hysteretic characteristics,deformation capacity and bearing capacity,of the large grid size shear walls.The test results indicate that vertical cracks at the ends of horizontal limbs extend over the entire height of the limb,horizontal cracks appear at the vertical limbs,concrete crashes at the bottom of the boundary vertical limbs,the hysteretic loops of the lateral load-displacement are pinch,the ultimate drift ratio is not less than 1/60.The elastic finite element analysis shows that the large grid size RC wall with thickness of 120mm can be equalized to the RC shear wall with thickness of 60mm.Its bending capacity under compressive force can be calculated by the current code formula for the RC shear wall with thickness of 60mm,but a reduction factor of 0.9 should be multiplied.Earthquake resistant calculating results of an engineering example show that the large grid size RC grillage wall system is suitable for the 6-story or less residence building which the seismic fortification intensity is 8.
What problem does this paper attempt to address?