Loss of flow accident and its mitigation measures for nuclear systems with SCWR-M

Zhihong Xu,Dong Hou,ShengWei Fu,Yanhua Yang,Xu Cheng
DOI: https://doi.org/10.1016/j.anucene.2011.08.020
IF: 1.9
2011-01-01
Annals of Nuclear Energy
Abstract:Based on a revised version of RELAP5, which can be used for super-critical pressure calculation, a model of mixed spectrum SCWR (SCWR-M) system is established. To analyze the transient behavior of SCWR-M and develop mitigation measures during loss of flow accident (LOFA), some important parameters, e.g. reactor coolant pump (RCP) coast-down time, Reactor Pressure Vessel (RPV) upper water volume and safety injection flow, etc., are chosen for the parametric analysis. The results achieved so far indicate that the SCWR-M system design is feasible and promising. Three important mitigation measures for LOFA of SCWR-M are derived from the results: RCP coast-down time of more than 15 s, RPV upper water volume of more than 27 m(3), and safety injection of more than 5% of the system design flow. (C) 2011 Elsevier Ltd. All rights reserved.
What problem does this paper attempt to address?