Remixing Control For Divided-Wall Columns

Hao Ling,Zhi Cai,Hao Wu,Jun Wang,Benxian Shen
DOI: https://doi.org/10.1021/ie201610g
2011-01-01
Abstract:The divided-wall column is an energy saving promising technology for the separation of ternary mixtures, but control. is difficult because of its complexity structure and interactions Of control loops. Although a few control methods have been reported, the general control method for all ternary mixtures is still Pending because of the difference of relative volatilities. In this work we explore a new control structure by control the remixing of the intermediate. at the top trays in the prefractionator section for the separation of benzene, toluene, and o-xylene. It is found that avoiding the remixing of toluene helps the column work very close to the optimal conditions. The remixing of toluene is studied at steady state first: Then; a remixing control structure with one remixing control loop and three composition control loops is presented. Minimized energy consumption is achieved by avoiding the remixing of toluene at the top of the prefractionator. Disturbances in feed flow rate and feed compositions are used to demonstrate the effectiveness of the proposed control structure. Remixing profile analysis of intermediate compounds gives an easy and new way to design and control the divided wall column at energy saving conditions.
What problem does this paper attempt to address?