Mixing performance of helical secondary-flow mixer used in coagulation

LIU Dan,Zhongguo Zhang,ZHAO Kehui,Zhaokun Luan,CHENG Yanjun,Jiding Li,RONG Liming,SONG Yun
DOI: https://doi.org/10.3969/j.issn.0438-1157.2011.10.005
2011-01-01
Abstract:The effects of curvature, pitch, tube length, flow rate and GT value (the product of root-mean-square velocity gradient and detention time) of a helical secondary-flow mixer used in coagulation with polyaluminum chloride (PACl) on its performance were investigated. The helical secondary-flow mixer was prepared by twining a rubber tube round a cylinder, and kaolin suspension was used as simulated wastewater for this experiment. It was found that tube length, curvature and flow rate of the mixer had highly significant impacts on mixing effect, similarly pitch had significant impact. And the impacts of the four factors decreased as follows: tube length, flow rate, curvature and pitch. 12 m was the optimal tube length among three tube lengths of 12 m, 18 m and 24 m. As for electrically neutral coagulation, the secondary-flow mixer with a tube length of 24 m also achieved an excellent mixing effect. In addition, there existed two optimal GT values for both electrically neutral and sweep coagulation. The optimal GT values were 21000 and 35000 for the former, and 19000 and 32000 for the latter. © All Rights Reserved.
What problem does this paper attempt to address?