A Sensitive Hydrogen Peroxide Sensor Based on Hemoglobin Immobilized on Gold Nanoparticles and 1,6-Hexanedithiol Modified Gold Electrode

Chenyao Liu,Shuoqi Li,Jiao,Wei Cao,Jingbo Hu,Qilong Li
DOI: https://doi.org/10.1080/00032711003790015
2011-01-01
Analytical Letters
Abstract:Hemoglobin (Hb) was successfully immobilized on a gold electrode modified with gold nanoparticles (AuNPs) via a molecule bridge 1,6-hexanedithiol (HDT). The AFM images suggested that the HDT/gold electrode could adsorb more AuNPs. UV-vis spectra indicated that Hb on AuNPs/HDT film retained its near-native secondary structures. The electrochemical behaviors of the sensor were characterized with cyclic voltammetric techniques. The resultant electrode displayed an excellent electrocatalytical response to the reduction of hydrogen peroxide (H(2)O(2)). The linear relationship existed between the catalytic current and the H(2)O(2) concentration ranging from 5.0 x 10(-8) to 1.0 x 10(-6) mol . L(-1). The detection limit (S/N = 3) was 1.0 x 10(-8) mol . L(-1).
What problem does this paper attempt to address?