Direct Electron Transfer and Enzymatic Activity of Hemoglobin in a Hexagonal Mesoporous Silica Matrix
ZH Dai,SQ Liu,HX Ju,HY Chen
DOI: https://doi.org/10.1016/j.bios.2003.08.024
IF: 12.545
2003-01-01
Biosensors and Bioelectronics
Abstract:The direct electrochemistry of hemoglobin (Hb) immobilized on a hexagonal mesoporous silica (HMS)-modified glassy carbon electrode was described. The interaction between Hb and the HMS was investigated using UV-Vis spectroscopy, FT-IR, and electrochemical methods. The direct electron transfer of the immobilized Hb exhibited two couples of redox peaks with the formal potentials of −0.037 and −0.232V in 0.1M (pH 7.0) PBS, respectively, which corresponded to its two immobilized states. The electrode reactions showed a surface-controlled process with a single proton transfer at the scan rate range from 20 to 200mV/s. The immobilized Hb retained its biological activity well and displayed an excellent response to the reduction of both hydrogen peroxide (H2O2) and nitrate (NO2−). Its apparent Michaelis–Menten constants for H2O2 and NO2− were 12.3 and 49.3μM, respectively, showing a good affinity. Based on the immobilization of Hb on the HMS and its direct electrochemistry, two novel biosensors for H2O2 and NO2− were presented. Under optimal conditions, the sensors could be used for the determination of H2O2 ranging from 0.4 to 6.0μM and NO2− ranging from 0.2 to 3.8μM. The detection limits were 1.86×10−9M and 6.11×10−7M at 3σ, respectively. HMS provided a good matrix for protein immobilization and biosensor preparation.