Measurement of the magnet blocks for SSRF insertion devices

Yongzhou He,Jidong Zhang,Qiaogen Zhou,ZhenMei Qian,Yang Li
DOI: https://doi.org/10.1063/1.3463258
2010-01-01
AIP Conference Proceedings
Abstract:Two in-vacuum undulators IVU25s and one elliptically polarized undulator EPU100 have been developed for SSRF. Two IVU25s with the same hybrid design contain about 640 Sm(2)Co(17) magnet blocks and the dimension of blocks is 65 W x 25H x 9D. The EPU100 of the APPLE-II type contains about 690 NdFeB magnet blocks with the dimension of 35W x 35H x 25D. This paper describes the magnetic measurements of these magnet blocks with the Helmholtz coil measurement system for IVU25 magnet blocks and the Hall probe measurement system for EPU100 magnet blocks. The measured maximum magnetic moment deviation and the maximum angle deviation are less than +/- 1.0% and 1.1 degrees respectively both for Sm(2)Co(17) blocks and NdFeB blocks and satisfy the specifications of undulators.
What problem does this paper attempt to address?