Design of Twin-Plane Electrical Resistance Tomography System

崔自强,王化祥,许燕斌,范文茹
DOI: https://doi.org/10.3969/j.issn.0493-2137.2010.02.004
2010-01-01
Abstract:In order to extend the measurement range of electrical resistance tomography(ERT),a twin-plane ERT system with voltage-driving/current-measuring strategy has been put forward,which can overcome voltage saturation resulting from the increase of resistance load.Based on analysis of the disadvantages of the asynchronous driving mode in twin-plane ERT system,a synchronous driving mode has been proposed and the finite element method based on three-dimensional field has been introduced.Experimental results show that the root mean square error of relative variation of the measured data is less than 0.15% and the standard deviation value of channel consistency ranges from 0.03% to 0.12%,which proves good measurement repeatability and channel consistency of the system.Experiments of gas/liquid two phase flow in the vertical pipe indicate that the measurement range of the system is significantly extended and online measurement of the two-phase flow is facilitated by the proposed twin-plane ERT system,which helps to realize online monitoring of flow regime classification and gas holdup computation.
What problem does this paper attempt to address?