A Novel Approach to Assess the Shunt-Flow Volume of Atrial Septal Defect

WANG Yong-shi,DONG Li-li,SHU Xian-hong,PAN Cui-zhen,ZHOU Da-xin
DOI: https://doi.org/10.13929/j.1003-3289.2010.11.023
2010-01-01
Abstract:Objective To assess the shunt-flow volume in the atrial septal defect(ASD)patients and the influence factors of it with vector flow mapping(VFM)technique.Methods Twenty ostium secundum ASD patients were enrolled.VFM technique was used to obtain the velocity distribution images and the shunt flow volume when placing the sample line at the maximum diameter of the defect measured with DSA-RS1 software.The correlation between shunt-flow volume and ratio of pulmonary flow to systemic blood flow(Qp/Qs),the maximum diameter of the defect,left and right atrial pressure and their difference value were analyzed.Results The shunt flow volume acquired with VFM was correlated well with Qp/Qs(r=0.93,P0.01).Magnitude of shunting was determined by the size of the defect(r=0.95,P0.05).The shunt-flow volume negatively correlated with left atrial systolic pressure(r=-0.61,P0.05)and the difference of systolic pressure between left and right atria(r=-0.57,P0.05).No correlation was found among shunt flow volume and right atrial systolic pressure,the difference of diastolic or mean pressure between two atria(all P0.05).Conclusion Vector flow mapping(VFM)is an ideal method to measure the shunting of ASD and evaluate right chamber flow dynamics.