Effect of Ph on Phosphorus Removal in Sequencing Batch Reactor with Single-Stage Oxic Process

丁艳,王冬波,李小明,杨麒,曾光明
2010-01-01
Abstract:To investigate the effect of pH on biological phosphorus removal in single-stage oxic process, two lab-scale sequencing batch reactors(SBRs) were operated(R1:pH 8±0.2;R2:pH 7±0.2) using synthetic wastewater, and variations of the main intracellular polymer during a cycle were also compared to discuss the probable reasons for different performances of phosphorus removal.Both R1 and R2 performed well in phosphorus removal, 94.9% and 83.5% of the average efficiencies of phosphorus removal in R1 and R2 were respectively obtained, suggesting that the effect of pH on phosphorus removal was slight in such a single-stage oxic process.The reason for the higher performance of phosphorus removal in R1 was its stronger dependence on polyphosphate.During the aerobic period, the accumulation of glycogen by bacteria in R1 was lower than that in R2(R1:1.42mmol/g, R2:1.55mmol/g), but the degradation of glycogen in R1 was higher than that in R2(R1:1.41mmol/g, R2:1.19mmol/g);in the idle phase, glycogen in R2 degraded obviously while that in R1 seldom degraded.Besides, though obvious phosphorus release was observed in both R1 and R2, the content of phosphorus released in R1 was higher than that in R2(R1:9.65mg/L, R2:7.33mg/L).A slight decrease and increase of PHA were respectively observed during the aerobic and the idle periods in R2 while no obvious change of PHA was found in R1 during the whole period.
What problem does this paper attempt to address?