Study on simulation and experiment of concentration diffusion of tracer in stirred tank
Xin-xin LI,Min-qi XIANG,Zhen-feng HUANG,Yuan-feng DENG,Gang CHENG,Rui PAN
DOI: https://doi.org/10.13624/j.cnki.issn.1001-7445.2018.0947
2018-01-01
Abstract:CFD software Fluent was used to simulate the flow field of agitator tank with different parameters of circular agitator tank with single layer and two blades, including blade angle, height of blade from the bottom, blade width, blade diameter and horizontal feeding point. The effects of three indexes, including mixing time, stirring power and unit volume mixing power, were analyzed, and the experimental study of different blade angle and height of blade from the bottom on tracer concentration were carried out, and concentration was measured by electroconductibility and was compared with the result of simulation. The results show that the index of unit volume mixing power can be used for agitator tank parameter optimization, and under the single factor consideration, blade angle is optimization as 20°, height of blade from the bottom 500 mm, blade width 80 mm, blade diameter 300 mm and horizontal feeding point 100mm. Also, it is noted that the correlation coefficient of tracer NaCl concentration variation curves between the experiments and the simulations is from 0. 77, to 0. 86) . This study makes it possible for agitator tank parameter optimization with numerical simulation.