Experimental Study of Static Sealing Structure with Large Diamter and Sealing Gap Using Magnetic Fluid

De-cai LI,Wen-ming YANG
2010-01-01
Abstract:In some special applications, especially in the military industry, magnetic fluid is needed in static seal at large sealing gaps and diameter. Static sealing structures whose diameter is larger than 390mm and sealing gaps are 1.1mm,1.5mm,2.0mm and 2.5mm respectively and apparatus verified their pressure-resisting capability were designed and assembled. The pressure-resisting capabilities of the sealing structures were measured by the apparatus under the different sealing gaps injection volumes of magnetic fluid, saturated magnetization intensities of the magnetic fluid and temperatures. The experimented results show that the maximum pressure-resisting capabilityies of these sealing structures are 20%,13%,8% and 4% of that of the structure in common use at the appropriate injection volumes of magnetic fluid of 70mL,70mL,120mL and 120mL; the pressure-resisting capabilities of the sealing structures are not sensitive to the change of temperature in the range of 20~120℃.
What problem does this paper attempt to address?