Experimental Study on HC1 Real-time Emission Characteristics in Simulated Municipal Solid Waste Incineration

FENG Li,JIANG Xu-guang,LI Chun-yu,AN Chun-guo,YAN Jian-hua
2010-01-01
Abstract:According to the composition of municipal solid waste, simulated municipal solid waste (SMSW) was prepared and used in the tests. The chlorine content of SMSW was regulated by adding different content of organic chloride(PVC) and inorganic chloride(NaCl), and a lab-scale tube furnace was applied to investigate the emission characteristics of HCl during SMSW incineration. The gaseous HCl emission was measured by Fourier transform infrared spectrometer(FTIR). Results show that compared to the combustion of SMSW with NaCl, the HCl concentration is relatively higher in the incineration of SMSW with PVC. With the chlorine content increasing, the HCl absorption from SMSW combustion with PVC quickly increases. However, there is no significant change in the case of SMSW incineration with NaCl. The HCl release beginning temperature in the incineration of SMSW with PVC is around 250°C and the maximum concentration value of HCl occurs at 300°C. Gaseous HCl emission can be detected above 900°C in SMSW incineration with NaCl. © 2010 Chin. Soc. for Elec. Eng.
What problem does this paper attempt to address?