Sensitivity Distribution of Electrodynamic Sensor Array

GAO He-ming,Xu Chuan-long,Wang Shi-min
DOI: https://doi.org/10.13334/j.0258-8013.pcsee.2010.05.019
2010-01-01
Abstract:In pneumatic conveyed powder flow, the charged particle contains rich information on gas-solid flow, including the velocity, concentration, particle size and so on. The electrodynamic sensor array can be used to get the information. However, due to its inhomogeneity, the different flow patterns may cause measurement error of the particle flow parameters. Based on unity point charge, the mathematic model of the electrodynamic sensor array was established, and the 3 dimensional electrostatic field in the sensing zone of the sensor was solved using finite element method. The effects of structural parameters of the electrodynamic sensor(including dimension of the electrode, the length and radius of the shielding, the thickness of the insulated pipe and so on) were investigated systematically. Theoretical analysis and experiments were also performed. The results show that the simulation is accurate, which provides a theoretical basis for the performance improvement and design of the sensor. © 2010 Chin.Soc.for Elec.Eng.