Measurement Method for Molten Metal Level Based on Temperature Field Distribution

Jun LIU,Da ZHANG,Zhen-wei HU,Jian-bin LEI,Zhi XIE
DOI: https://doi.org/10.3969/j.issn.1000-1158.2010.05.15
2010-01-01
Abstract:Based on temperature field distribution, a new method for molten metal level measurement is put forward to solve the problem that high-temperature of molten metal and the flux slag on upper layer make it difficult to measure the molten metal level accurately in the metallurgy industry. By means of analyzing temperature distribution of different layers in continuous casting container, including the air layer, the slag layer and the molten metal layer, a method of maximum temperature gradient location is transformed to interfaces location, and the molten steel level is measured accurately finally. The result of field measurement shows the measuring error is less than 5 mm.
What problem does this paper attempt to address?