Accuracy of dental implant surgery with robotic position feedback and registration algorithm: An in-vitro study
Kang-Jie Cheng,Tian-Shu Kan,Yun-Feng Liu,Wei-Dong Zhu,Fu-Dong Zhu,Wei-Bin Wang,Xian-Feng Jiang,Xing-Tao Dong,Kang-jie Cheng,Tian-shu Kan,Yun-feng Liu,Wei-dong Zhu,Fu-dong Zhu,Wei-bin Wang,Xian-feng Jiang,Xing-tao Dong
DOI: https://doi.org/10.1016/j.compbiomed.2020.104153
IF: 7.7
2021-02-01
Computers in Biology and Medicine
Abstract:<h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Background</h3><p>The purpose of this study was to develop and validate a positioning method with hand-guiding and contact position feedback of robot based on a human-robot collaborative dental implant system (HRCDIS) for robotic guided dental implant surgery.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Methods</h3><p>An HRCDIS was developed based on a light-weight cooperative robot arm, UR5. A three-dimensional (3D) virtual partially edentulous mandibular bone was reconstructed using the cone bone computed tomography images. After designing the preoperative virtual implant planning using the computer software, a fixation guide worn on teeth for linking and fixing positioning marker was fabricated by 3D printing. The fixation guide with the positioning marker and a resin model mimicking the oral tissues were assembled on a head phantom. The planned implant positions were derived by the coordinate information of the positioning marker. The drilling process using the HRCDIS was conducted after mimicking the experimental set-up and planning the drilling trajectory. Deviations between actual and planned implant positions were measured and analyzed.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Results</h3><p>The head phantom experiments results showed that the error value of the central deviation at hex (refers to the center of the platform level of the implant) was 0.79±0.17 mm, central deviation at the apex was 1.26±0.27 mm, horizontal deviation at the hex was 0.61±0.19 mm, horizontal deviation at the apex was 0.91±0.55 mm, vertical deviation at the hex was 0.38±0.17 mm, vertical deviation at the apex was 0.37±0.20 mm, and angular deviation was 3.77±1.57°.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Conclusions</h3><p>The results from this study preliminarily validate the feasibility of the accurate navigation method of the HRCDIS.</p>
engineering, biomedical,computer science, interdisciplinary applications,mathematical & computational biology,biology