Abstract:A novel space environment simulator (SES) system was set up which consists of closed-loop fluid handling system, low and high temperature air generator system, irregular shaped cavity system, and control and data acquisition system. This experimental system can provide high and low temperature test environments by spraying liquid N2 and electric heating, the pressure in the cavity can be controlled with high precision pressure adjusting system. The thermal characteristics of the SES were investigated experimentally. The experimental results show that the SES system can provide high temperature uniformity and appropriate temperature variation rate, the temperature distributions of both high and low experiment conditions are within ±3°C range. The temperature variation rate can be easily controlled by changing the differences between inlet gas temperature and recycle gas temperature, but the temperature uniformity inside cavity and temperature variation rate must be considered synthetically.