Thermophoretic Deposition of Sub-micro Particles in Tube Flows

ZHOU Tao,YANG Rui-chang,HU Yu,ZHAO Lei,WANG Shi-chao,LIU Ruo-lei,FU Tao
DOI: https://doi.org/10.3321/j.issn:1000-6761.2009.06.014
2009-01-01
Abstract:From measurements of a designed experimental system,calculation formula for thermophoretic deposition efficiency of sub-micro particles was derived. Experimental results demonstrate that compared with long tube,short tube makes good use of simultaneous developing flow of velocity and temperature,and therefore produces higher deposition efficiency.Based on step-by-step principles,a precipitator,taking short tube as its thermophoretic deposition section,was designed,in which the thermophoretic deposition and transition section are alternatively arranged.Results show that when 8 such thermophoretic deposition sections are used,the total removal efficiency can reach 83.24%,indicating that it is possible to design applicable precipitators for removal of sub-micro particles based on the step-by-step principle.
What problem does this paper attempt to address?