Synchronous Discharge Characteristics of Multi Gap Multi Channel Gas Switch

LIU Xuan-dong,SUN Feng-ju,LIANG Tian-xue,JIANG Xiao-feng,QIU Ai-ci,FEI Guo-qiang,ZENG Jiang-tao,LIU Zhi-gang
DOI: https://doi.org/10.13336/j.1003-6520.hve.2009.03.010
2009-01-01
Abstract:Large accelerators based on linear transformer driver (LTD) technology will require hundreds to tens of thousands of multi-gap multi-channel gas switch (MMCS) discharging synchronously. Low inductance, low jitter, low prefire probability and nice synchronous performance are requisite characteristics of these switches. In this paper, the configuration of the electrodes and envelop of the available 200 kV MMCS are optimized by the electric field distribution of the switch. Convex ring electrodes are used to instead of the plane rings. The envelop of the switch adopts lucite instead of the previous nylon. The electric field simulation indicates that the voltage distribution of switch is improved obviously. The experimental results of the self-breakdown and triggered-breakdown are presented. A test circuit is established in a geometry that resembles single discharge circuit called brick of LTD. Ten circuits are arranged in parallel, and then the synchronous discharge of 10 switches is carried out. The result indicates that 5 switches can discharge synchronously. When these switches are filled with 0.14 MPa nitrogen, and charged with ±60kV, the output current pulse is approximately 100 kA, and the rise time is 100 ns.