Adaptive Clutter Rejection for Ultrasound Color Flow Imaging Based on Recursive Eigendecomposition

Wei You,Yuanyuan Wang
DOI: https://doi.org/10.1109/tuffc.2009.1304
2009-01-01
Abstract:In the conventional eigenfilter used to reject clutter components of ultrasound color flow imaging, input samples are required to be statistically stationary. However, clutter movements may vary over the depth of the imaged area, which makes the eigenfilter less efficient. In the current study, a novel clutter rejection method is proposed based on the recursive eigendecomposition algorithm. In this method, the current eigenvector matrix of the ultrasound echo correlation matrix, which will be used to construct the clutter subspace, is determined by previous eigenvector matrices and the current input. After the estimated clutter signal is obtained by projecting the original input into the clutter space, each filtered output is eventually obtained by subtracting the estimated clutter signal from the original input. This procedure is iterated for each sample volume along the depth. During the updating process, a forgetting factor is introduced to determine proper weights for different inputs. Simulated data in 3 situations and in vivo data collected from human carotid arteries are used to compare the proposed method with other popular clutter filters. Results show that the proposed method can achieve the most accurate velocity profiles in all simulation situations and introduces the fewest velocity artifacts in the tissue region in the in vivo experiment.
What problem does this paper attempt to address?