Experimental Study and Theoretic Analysis of Steel Fiber Reinforced Concrete Six-Pile Thick Caps with Double-Column

LI Jixiang,ZHANG Yuanyuan,LIU Xiaofan
DOI: https://doi.org/10.3321/j.issn:1000-6869.2009.02.019
2009-01-01
Abstract:In order to study the mechanics model and load-transferring pattern,6 specimens were tested by static loading and analyzed by nonlinear finite element method.The mechanical behavior such as cracking load,limit load,distribution of strain inside caps and stress of the bars for steel fiber reinforced concrete(SFRC) double-column combined with six-pile caps(DCPC) are discussed.The results indicate that steel fiber could increase the cracking load and limit load for reinforced concrete caps,as the cracking and further growth cracks.The failure mode of SFRC double-column combined with six-pile caps as punching damage and the load-transfer can be explained by spatial strut-and-tie method(STM).A bearing force formula based on the failure of the STM is presented,and the calculation results agrees with the experiments very well.Finally,some suggestions of DCPC design based on STM are given for the application of the STM in practice.
What problem does this paper attempt to address?