Stability Research on Elliptic Paraboloid Suspen-Dome of Changzhou Municipal Gymnasium

罗斌,郭正兴,冯远,王立维,王永泉
DOI: https://doi.org/10.14006/j.jzjgxb.2009.06.020
2009-01-01
Abstract:The steel roof of the Changzhou Municipal Gymnasium is a suspen-dome structure, which consists of levy cable-strut system and single-layer reticulated shell. Compared with conventional suspend-domes, this suspend-dome with an elliptic paraboloid has a greater span(120m) and a rise-span ratio (1/3.7). Through member buckling analysis, linear and geometric nonlinear buckling analysis, comparative studies on stability of suspend-dome and single-layer shell were conducted to understand the influence of cable-strut system on the stability of the suspend-dome of high rise-span ratio, which was the key failure mode. Cable-strut system enhances the structural integrity, decreases the sensitivity to initial geometric defect, but influences little on structural stiffness, fundamental natural period and mode, member buckling load, linear buckling load, geometric nonlinear buckling load without initial geometric defect and buckling modes. The suspen-dome of high rise-span ratio is still sensitive to initial geometric defect and the stability is still one of design control factors. Because the use of the elliptic paraboloid surface, the distribution patterns of live load influences greatly on buckling modes of the structure, and the uniform live load with full span is not always the most dangerous.
What problem does this paper attempt to address?